Context

The HTML report has a per-scenario timing waterfall (IMPROVEMENT-PLAN §12, N6a) derived purely from each step’s duration_ms. It cannot show cross-worker occupancy — which scenarios ran concurrently, on which of the --jobs workers — because the sans-IO core reads no clock and the event stream carries no wall-clock timestamp or worker identity.

The core’s purity is deliberate (deterministic snapshots/properties). ADR-0012 established the escape valve: values the core must not compute (config) are injected at the CLI edge. run_id is already such a value — the core carries it (RunStarted.run_id) but the CLI generates it. The same pattern extends to timing.

Decision

  • Add two optional, additive fields to the ScenarioStarted and ScenarioFinished events: timestamp_ms: Option<u64> (milliseconds since the run began) and worker: Option<u64> (0-based worker index). Both are #[serde(default, skip_serializing_if = "Option::is_none")], so old records parse unchanged and single-threaded/None cases serialize identically (ADR-0008 additive-only). They are kept off RunStarted, whose exact wire bytes are pinned.
  • The core leaves them None — it carries fields it never fills, exactly as it carries a run_id it never generates (sans-IO preserved). The CLI wraps the event sink in a stamping closure: EventSink::new(move |ev| inner.emit(&stamp(ev))). stamp runs on the worker thread (emit is synchronous, called from the scenario worker), so it reads the run-start Instant and maps thread::current().id() → a stable 0-based index there, at the edge. The core never sees a clock or a thread id.
  • Errata (2026-08-11): only ScenarioStarted carries a worker. As implemented, ScenarioFinished is emitted from the main dispatcher thread, not the worker that ran the scenario, so stamping a thread index there would name the wrong one; it carries the end timestamp and worker: None. The worker identity comes from ScenarioStarted, which is emitted on the worker thread, and the timeline pairs the two. EVENTS.md has always described it this way — the bullet above did not.
  • The HTML report gains a run-level timeline: a lane per worker, each scenario a bar from its start to its finish timestamp — the Gantt/occupancy view. It renders only when the stamps are present; a record without them falls back to the N6a per-scenario waterfall alone. The view stays a pure function of the (now richer) event record.

Consequences

  • Core stays sans-IO; the injection is the established run_id/config pattern.
  • The JSONL record gains observability fields, additively (ADR-0008 — still the one record; no sidecar timing file).
  • Snapshot honesty: old records parse unchanged, but every event in a new run now carries a (non-deterministic) timestamp_ms, so the reference_event_stream snapshot changes — it needs a new insta filter ("timestamp_ms":\d+ → 0) plus a deliberate cargo insta review. This is allowed (the same deliberate-acceptance policy as emitter changes), and is called out rather than glossed. The HTML snapshot likewise regenerates.
  • Enables the cross-worker timeline; the derived HTML view remains pure over the record.

Alternatives considered

  • Stamp inside the core — rejected: reading a clock in proef-core breaks the sans-IO invariant that makes snapshots and property tests deterministic.
  • A second sidecar timing file — rejected: ADR-0008 makes the JSONL event stream the record; a parallel timing artifact is a second record format.
  • Derive occupancy from duration_ms alone (no injected fields) — impossible: without an absolute clock there is no way to know which scenarios overlapped in wall-clock time; only the sequential per-scenario waterfall (N6a) is derivable, which is why it shipped first.
  • Wall-clock (unix ms) instead of run-relative — rejected: run-relative starts the timeline at 0, is cleaner to render, and avoids putting absolute wall-clock in the record.